In order to better guarantee the product quality of wireless modules, Think Wireless sends the wireless modules it produces to the laboratory for inspection and testing. The inspection items include safety testing, climate and environmental testing, electromagnetic compatibility testing, etc. The specific test values of various technical indicators are as follows.
1. Electrostatic discharge test
Test result: meet the requirements
Test result: meet the requirements
Connection diagram of electrostatic discharge test layout:
2. Radio frequency continuous wave conduction test
Test method and standard requirements: The sample under test is in normal working condition, and 80℅AM (1kHz) sinusoidal modulation signal is applied to the AC power terminal and signal terminal, the test voltage is 3V, and the frequency range is 0.15-80MHz. Should meet performance criterion A.
Inspection result: meet the requirements
Connection diagram of radio frequency continuous wave conduction test layout:
3. Radio frequency electromagnetic field test
Test method and standard requirements: The sample under test is in normal working condition, and 80℅AM (1kHz) sinusoidal modulation signal is applied to the AC power terminal and signal terminal, the test field strength is 10V/m, and the frequency range is 80-1000MHz. Should meet performance criterion A.
Inspection result: meet the requirements
Connection diagram of radio frequency electromagnetic field test arrangement:
4. Electrical fast transient test
Inspection result: meet the requirements
Electrical fast transient test layout connection diagram:
5. Voltage sag test
Inspection result: meet the requirements
Inspection result: meet the requirements
6. Short-term voltage interruption test
Detection method and requirements: The tested sample is in normal working condition, and the AC power port of the tester is used to input a rated voltage of <5% for 250 cycles. Should meet the performance criterion C.
Inspection result: meet the requirements
Connection diagram of test arrangement for voltage sag and short-term interruption of voltage:
7. Surge test
Testing method and requirements: The test sample is in normal working condition, and the surge signal generator is used to apply the surge combined wave signal to the AC power terminal of the test sample. The number of applications: positive and negative polarity 5 times each, repetition rate: 1 Times/1 minute, applied voltage: line-line: 1kV; line-ground: 2kV. Should meet performance criterion B.
Inspection result: meet the requirements
Surge test layout connection diagram:
The above is the test report of NiceRF Wireless's wireless module products. All technical indicators have reached the standard requirements. Its good performance is obvious, and it is a high-quality wireless module.